IS : 1719 - 1969
   
  back
 

TABLE 1 PHYSICAL REQUIREMENTS FOR FELT (Clause 3.1)
SL. No.
Characteristic
Requirement
Tolerance
Method of Test
1
Length
As agreed. In case of
partial delivery, as
marked or declared.
(See Note 1)
----
IS: 1954-1969
2
Width, cm
132 or as agreed.
+/- 1
IS: 1954-1969*
3
Thickness
As agreed (See Note 2)
Up to 3: +/-15%
3 upto 16: +/-10%
Above 16: +/- 5 %

+/- 10%
Appendix B

Appendix C
4
Density, g/ccm3

a) Extra Hard
b) Hard
c) Medium Hard
d) Soft
0.33
0.24
0.18
0.15
----
----
5
Tensile strength, k

a) Extra Hard
b) Hard
c) Medium Hard
d) Soft
24
14
9
See Note 3
----
----
6
Spliting resistance, on
2.5x15 cm strips,
Min (See Note 4)
1.25
----
Appendix D

Methods for determination of length and width of fabrics (first revision)


Note 1
The usual piece length of felt are 4 and 14 metres.
Note 2
The common thickness of felt are 1.5,3,6,10,13,16,19,22 and 25 mm
Note 3
This test is not to be carried out on soft variety of felt.
Note 4
This test is not to be carried out on soft & medium hard varieties of felt and also on felthaving thickness of 6 mm or below.


    back
 
|
|
|
Copyright © 2007. All rights reserved by Pugalia woollen mills p. ltd.